Furnace

Goodman Furnace error codes

86 codes across 6 model families. Start with your model number, because Goodman reuses the same numbers for different faults on different boards.

Goodman shares code tables with other brands

Goodman, Amana and Daikin furnaces run on shared control platforms, so they share code tables. The same number can mean different things on different Goodman model families.

Find your model family

The model number is on the data plate, usually on the side or back of the unit or behind the service panel. It usually starts with the letters or numbers in the name below.

GMVM96

Goodman and Amana GMVM96, GMVM97, GCVM96 alphanumeric codes

2010s · 26 codes

26 codes
Goodman GMVM96 furnace error codes, what each one means and how urgent it is
CodeWhat it meansHow urgent
E0Lockout after too many ignition retriesCritical
E1Low stage pressure switch stuck closed at start of heatHigh
E2Low stage pressure switch stuck openCritical
E3Open high limit switchHigh
E4Flame detected when no flame should be presentCritical
E5Open low voltage fuseHigh
E6Low flame signalHigh
E7Igniter fault or improper groundingHigh
E8High stage pressure switch stuck closed at start of heatHigh
E9High stage pressure switch stuck openHigh
EAReversed 115 volt polarityHigh
ECInducer motor overcurrent faultHigh
EFAuxiliary input openLow
EdRollout switch openCritical
b0Blower motor not runningHigh
b1Blower communication errorHigh
b2Blower horsepower mismatchHigh
b3Blower motor running in power, temperature or speed limitHigh
b4Blower motor current trip or lost rotorHigh
b5Blower motor locked rotorHigh
b6Blower motor voltage or over temperature tripHigh
b7Incomplete parameters sent to motorHigh
b9Low indoor airflowHigh
d0Data not yet on networkModerate
d4Invalid memory card dataHigh
IFInternal control faultHigh
Open the GMVM96 code list →

GMVC95

Goodman and Amana GMVC95, GCVC95, GCVC96 alphanumeric codes

2000s-2010s · 23 codes

23 codes

Similar to GMVM96 but has no rollout code, which changes the safety story.

Goodman GMVC95 furnace error codes, what each one means and how urgent it is
CodeWhat it meansHow urgent
E0Lockout after too many ignition retriesCritical
E1Low stage pressure switch stuck closedHigh
E2Low stage pressure switch stuck openCritical
E3Open high limit switchHigh
E4Flame detected when no flame should be presentCritical
E5Open low voltage fuseHigh
E6Low flame signalHigh
E7Igniter fault or improper groundingHigh
E8High stage pressure switch stuck closedHigh
E9High stage pressure switch stuck openHigh
EAReversed 115 volt polarityHigh
b0Blower motor not runningHigh
b1Blower communication errorHigh
b2Blower horsepower mismatchHigh
b3Blower running in a protection limitHigh
b4Blower current trip or lost rotorHigh
b5Blower motor locked rotorHigh
b6Blower voltage or over temperature tripHigh
b7Incomplete parameters sent to motorHigh
b9Low indoor airflowHigh
d0Data not yet on networkModerate
d4Invalid memory card dataHigh
IFInternal control faultHigh
Open the GMVC95 code list →

GM9S96

Goodman GM9S96 and GR9S96 alphanumeric codes

2020s · 11 codes

11 codes

On this platform F01 to F09 are blower speed setup values in the installer menu, not faults. IdL means Idle, not 1DL.

Goodman GM9S96 furnace error codes, what each one means and how urgent it is
CodeWhat it meansHow urgent
IdLIdleNormal
FAnFan commandNormal
gHGas heat demandNormal
dFtDefrost demandNormal
F01Blower speed setup value 1Normal
EE0Lockout after repeated ignition failuresCritical
EAFFlame signal out of range during a heat cycleCritical
E1IIgnition faultCritical
EbLBlower fault, lower circuitHigh
EbUBlower fault, upper circuitHigh
EALAirflow fault, lower limitHigh
Open the GM9S96 code list →

APG13

Goodman and Amana APG13, GPG13, APG15 combined furnace and AC flash codes

2000s · 9 codes

9 codes

One LED counter is shared between the gas section and the cooling section, so furnace and AC codes cannot be separated.

Goodman APG13 furnace error codes, what each one means and how urgent it is
CodeWhat it meansHow urgent
1 flashIgnition failure, rollout open, or auxiliary limit openCritical
2 flashesOpen end centrifugal switchHigh
3 flashesClosed end centrifugal switch with no combustion motorHigh
4 flashesOpen high limit switchHigh
5 flashesFlame detected when no flame should be presentCritical
6 flashesCompressor time delay or short cycle timerModerate
7 flashesLimit opened five times in the same call for heatHigh
8 flashesIndoor or outdoor thermostat open, cooling onlyLow
9 flashesHeat pump or loss of charge switch open, cooling onlyHigh
Open the APG13 code list →

GMV / GMH / GMS / GMN

Goodman, Amana and Daikin legacy furnace flash codes (GMV, GMH, GMS, GMN series)

1980s-2000s · 9 codes

9 codes

One shared control table covers the whole legacy group, so these series are listed together. Not every series reports every code: the GMN, GMP and GMT group stops at 5 flashes, the GDS, GHS, GMS and GKS group stops at 7, and only the two-stage GMV reports 9. Each code page states which series it applies to.

Goodman GMV / GMH / GMS / GMN furnace error codes, what each one means and how urgent it is
CodeWhat it meansHow urgent
1 flashLockout after too many ignition triesCritical
2 flashesPressure switch stuck closedHigh
3 flashesPressure switch stuck openCritical
4 flashesHigh limit switch openHigh
5 flashesFlame detected when no flame should be presentCritical
6 flashesRollout switch openCritical
7 flashesLow flame signalHigh
8 flashesIgniter fault or bad groundingHigh
9 flashesHigh stage pressure switch stuck openHigh
Open the GMV / GMH / GMS / GMN code list →

GMSS9 / GCSS9

Goodman and Amana GMSS9, GCSS9, AMSS9, ACSS9 flash codes

2000s · 8 codes

8 codes

A Honeywell-platform control with its own wording and its own code assignments. It is not the GMV table.

Goodman GMSS9 / GCSS9 furnace error codes, what each one means and how urgent it is
CodeWhat it meansHow urgent
1 flashFurnace lockout after 3 ignition retriesCritical
2 flashesPressure switch circuit closedHigh
3 flashesPressure switch circuit not closedCritical
4 flashesPrimary or auxiliary limit circuit openHigh
5 flashesFlame sensed with no call for heatCritical
6 flashesRollout limit open or control module fuse blownCritical
7 flashesFlame sense signal lowHigh
8 flashesProblem with igniter circuitHigh
Open the GMSS9 / GCSS9 code list →

Common questions

How many Goodman furnace error codes are documented here?
86 codes across 6 model families. Every code page lists what the fault means, the causes, the checks you can safely do yourself, and when it stops being worth resetting the unit.
How do I read the code on a Goodman furnace?
It depends which board you have. Some Goodman furnace families print the code as text, and others blink an LED that you count against a legend printed on the board. Check the table above, because the two are read in completely different ways.
Which Goodman furnace model do I have?
The model number is on the data plate, usually on the side or back of the unit or behind the service panel. The families on this page are GMVM96, GMVC95, GM9S96, APG13, GMV / GMH / GMS / GMN, GMSS9 / GCSS9. The model number starts with the letters or numbers in that name, which is the only reliable way to pick the right code table.
Do other brands share Goodman furnace codes?
Goodman, Amana and Daikin furnaces run on shared control platforms, so they share code tables. The same number can mean different things on different Goodman model families.