Mini Split
Fujitsu Mini Split error codes
24 codes across 1 model family. Start with your model number, because Fujitsu reuses the same numbers for different faults on different boards.
Find your model family
The model number is on the data plate, usually on the side or back of the unit or behind the service panel. It usually starts with the letters or numbers in the name below.
ASTG09 / ASTG12 / AOTG09 / AOTG12 KMTC
Fujitsu GENERAL AIRSTAGE KMTC wall split codes, indoor and outdoor
24 codes
ASTG09KMTC and ASTG12KMTC indoor units with AOTG09KMTC and AOTG12KMTC outdoor units on R32. A compatible non-polar wired controller shows the code directly on its display. The supplied wireless controller has no screen and shows the same codes as a flashing pattern on the indoor indicator lamps instead. The service reference gives a separate main PCB, control unit and inverter assembly identification for each of the two capacities, so a board from the wrong capacity is a recognised cause of codes 32 and 62.
| Code | What it means | How urgent |
|---|---|---|
| 11 | Serial communication error | High |
| 12 | Wired remote controller or server room control communication error | Moderate |
| 15 | Check run unfinished or automatic airflow adjustment error | Moderate |
| 18 | External communication error | Moderate |
| 23 | Combination error | High |
| 32 | Indoor unit PCB model information error | High |
| 35 | Manual auto switch error | Moderate |
| 41 | Room temperature sensor error | Moderate |
| 42 | Indoor heat exchanger middle temperature sensor error | Moderate |
| 44 | Human sensor error | Low |
| 51 | Indoor unit fan motor error | High |
| 62 | Outdoor unit main PCB model information or communication error | High |
| 63 | Inverter error | High |
| 64 | Active filter or power factor correction circuit error | High |
| 65 | Trip terminal L error | High |
| 71 | Discharge temperature sensor error | High |
| 73 | Outdoor heat exchanger liquid temperature sensor error | Moderate |
| 74 | Outdoor temperature sensor error | Moderate |
| 84 | Current sensor error | High |
| 94 | Trip detection | High |
| 95 | Compressor rotor position detection error | High |
| 97 | Outdoor unit fan motor 1 error | High |
| 99 | Four way valve error | High |
| A1 | Discharge temperature error, compressor over-temperature | High |
Common questions
- How many Fujitsu mini split error codes are documented here?
- 24 codes across 1 model family. Every code page lists what the fault means, the causes, the checks you can safely do yourself, and when it stops being worth resetting the unit.
- How do I read the code on a Fujitsu mini split?
- The control board prints the code as text, so you read it off the display rather than counting anything. Write the exact characters down, including any letter, because Fujitsu codes are short and easy to misread.
- Which Fujitsu mini split model do I have?
- The model number is on the data plate, usually on the side or back of the unit or behind the service panel. The family on this page are ASTG09 / ASTG12 / AOTG09 / AOTG12 KMTC. The model number starts with the letters or numbers in that name, which is the only reliable way to pick the right code table.