Appliance error code lookup
Search 394 codes three ways. By the code itself (E4, 1 flash). By brand and fault (Goodman flame sensor). Or by what the machine is actually doing (wont drain, no heat).
Every result names the model family it belongs to, because a code without one is not an answer.
394 codes indexed
Browse by equipment
Every code on the site
All 394 codes, grouped by equipment, if you would rather scroll than search. Every one names the model family the code belongs to.
Furnace86 codes
- 1 flashLockout after too many ignition tries
- 1 flashFurnace lockout after 3 ignition retries
- 1 flashIgnition failure, rollout open, or auxiliary limit open
- 2 flashesPressure switch stuck closed
- 2 flashesPressure switch circuit closed
- 2 flashesOpen end centrifugal switch
- 3 flashesPressure switch stuck open
- 3 flashesPressure switch circuit not closed
- 3 flashesClosed end centrifugal switch with no combustion motor
- 4 flashesHigh limit switch open
- 4 flashesPrimary or auxiliary limit circuit open
- 4 flashesOpen high limit switch
- 5 flashesFlame detected when no flame should be present
- 5 flashesFlame sensed with no call for heat
- 5 flashesFlame detected when no flame should be present
- 6 flashesRollout switch open
- 6 flashesRollout limit open or control module fuse blown
- 6 flashesCompressor time delay or short cycle timer
- 7 flashesLow flame signal
- 7 flashesFlame sense signal low
- 7 flashesLimit opened five times in the same call for heat
- 8 flashesIgniter fault or bad grounding
- 8 flashesProblem with igniter circuit
- 8 flashesIndoor or outdoor thermostat open, cooling only
- 9 flashesHigh stage pressure switch stuck open
- 9 flashesHeat pump or loss of charge switch open, cooling only
- b0Blower motor not running
- b0Blower motor not running
- b1Blower communication error
- b1Blower communication error
- b2Blower horsepower mismatch
- b2Blower horsepower mismatch
- b3Blower motor running in power, temperature or speed limit
- b3Blower running in a protection limit
- b4Blower motor current trip or lost rotor
- b4Blower current trip or lost rotor
- b5Blower motor locked rotor
- b5Blower motor locked rotor
- b6Blower motor voltage or over temperature trip
- b6Blower voltage or over temperature trip
- b7Incomplete parameters sent to motor
- b7Incomplete parameters sent to motor
- b9Low indoor airflow
- b9Low indoor airflow
- d0Data not yet on network
- d0Data not yet on network
- d4Invalid memory card data
- d4Invalid memory card data
- dFtDefrost demand
- E0Lockout after too many ignition retries
- E0Lockout after too many ignition retries
- E1Low stage pressure switch stuck closed at start of heat
- E1Low stage pressure switch stuck closed
- E1IIgnition fault
- E2Low stage pressure switch stuck open
- E2Low stage pressure switch stuck open
- E3Open high limit switch
- E3Open high limit switch
- E4Flame detected when no flame should be present
- E4Flame detected when no flame should be present
- E5Open low voltage fuse
- E5Open low voltage fuse
- E6Low flame signal
- E6Low flame signal
- E7Igniter fault or improper grounding
- E7Igniter fault or improper grounding
- E8High stage pressure switch stuck closed at start of heat
- E8High stage pressure switch stuck closed
- E9High stage pressure switch stuck open
- E9High stage pressure switch stuck open
- EAReversed 115 volt polarity
- EAReversed 115 volt polarity
- EAFFlame signal out of range during a heat cycle
- EALAirflow fault, lower limit
- EbLBlower fault, lower circuit
- EbUBlower fault, upper circuit
- ECInducer motor overcurrent fault
- EdRollout switch open
- EE0Lockout after repeated ignition failures
- EFAuxiliary input open
- F01Blower speed setup value 1
- FAnFan command
- gHGas heat demand
- IdLIdle
- IFInternal control fault
- IFInternal control fault
Heat Pump59 codes
- A0Indoor unit external protection device abnormality
- A1Indoor unit control board abnormality
- A3Drain level control system abnormality
- A6Indoor fan motor lock or overload
- A7Swing flap motor abnormality, warning
- A8Indoor unit power supply voltage abnormality
- A9Indoor unit electronic expansion valve abnormality
- AFDrain water level above the limit, warning
- AHSelf cleaning decoration panel abnormality
- AJCapacity setting error
- C1Transmission abnormality between the indoor and fan boards
- C4Indoor heat exchanger liquid pipe thermistor abnormality
- C5Indoor heat exchanger gas pipe thermistor abnormality
- C6Indoor unit and fan board combination error
- C9Suction air thermistor abnormality
- CADischarge air thermistor abnormality
- CCHumidity sensor system abnormality, warning
- CEInfrared presence or floor sensor error, warning
- CJRemote controller thermistor abnormality, warning
- E1Outdoor unit main board abnormality
- E3High pressure switch activation
- E4Low pressure protection activation
- E5Compressor motor lock
- E7Outdoor fan motor abnormality
- E9Outdoor electronic expansion valve abnormality
- F3Discharge pipe temperature abnormality
- F6Refrigerant overcharge
- H9Outdoor air thermistor abnormality, R1T
- J3Discharge pipe thermistor abnormality, R2T
- J5Suction pipe thermistor abnormality, R3T and R5T
- J6Outdoor heat exchanger deicer thermistor abnormality, R4T
- J7Outdoor heat exchanger liquid pipe thermistor abnormality, R7T
- J9Subcooling heat exchanger gas pipe thermistor abnormality, R6T
- JAHigh pressure sensor abnormality
- JCLow pressure sensor abnormality
- L1Inverter board abnormality
- L4Radiation fin temperature rise abnormality
- L5Compressor instantaneous overcurrent
- L8Compressor overcurrent
- L9Compressor startup abnormality
- LCTransmission error between the outdoor board microcomputers
- M1Centralized controller board defect
- M8Transmission error between centralized controllers
- MAPoor centralized controller combination
- MCAddress duplication and poor setting, warning
- P1Inverter circuit capacitor high voltage
- P4Radiation fin thermistor abnormality, warning
- U0Refrigerant shortage, warning that should not be ignored
- U2Power supply insufficient or instantaneous abnormality
- U3Check operation not executed
- U4Transmission error between indoor and outdoor units
- U5Transmission error between the controller and the indoor unit
- U8Transmission error between main and sub controllers
- U9Transmission error within the same system
- UAImproper indoor and outdoor unit combination
- UCCentralized controller address duplication, warning
- UETransmission error between the centralized controller and an indoor unit
- UFSystem not set yet
- UHSystem address undefined
Dishwasher49 codes
- 1EClogged filter, water not passing through
- 2HEstimated time remaining
- 3CPump operation error
- 3EIncoming water too hot
- 4CWater supply fault, will not fill
- 5CDrain fault, water not clearing the sump
- 7EWaterWall reflector fault
- 9CNot enough water to start the cycle
- AELeakage or overfilling detected
- APAccess point mode
- bEBubble error, too much foam
- bEControl panel button stuck
- CEControl panel communication failure
- CLControl lock is on
- E01Heat pump motor circuit fault at the main board
- E02Main control board relay fault
- E04Heater electronics failed the self test
- E05Wash arm diverter circuit fault
- E06Door sensor circuit fault
- E07Zeolite Crystal Dry fan motor defective
- E10Zeolite Crystal Dry chamber heater fault
- E12Limescale in the heat pump
- E14Flow meter fault or filling system problem
- E15Water in the base of the tub, leakage protection active
- E16Water not entering the machine
- E18Water flow too low to fill the tub
- E19Detergent dispenser solenoid circuit fault
- E20Heat pump internal heater fault
- E21Heat pump blocked
- E22Filter blocked, water not circulating
- E23Drain pump blocked, clogged, or faulty
- E24Water not draining
- E27House power supply too low
- F31Heat dry fan fault
- F35Heat dry temperature fault
- F37Auto open door fault
- HCOverheating or high temperature detected
- HEHeater error, water not heated or overheated
- IEInlet error, not enough water reached the tub
- LCLeak detected, water in the base
- LECleaning motor fault
- nESpray arm position motor fault
- OCOver-level water in the tub
- OEOutlet error, water not draining
- PCZone wash function error
- PEWater level sensor fault
- PEHalf load function error
- PFPower failure recorded
- tETemperature sensor fault
Washer47 codes
- 1EWater level sensor fault
- 3CMotor fault
- 3EMotor fault, or voltage on some models
- 4CNot filling, no water reaching the tub
- 4C2Supply water too hot for a cold fill
- 4ENot filling, no water reaching the tub
- 5ENot draining
- 6EStuck button or motor sensor, depends on model
- 7ESilverCare system fault
- 8CMEMS sensor fault
- 8EMEMS sensor fault
- 9CSupply voltage irregularity
- ACCommunication error between internal boards
- AECommunication error between internal boards
- CbCalibration or tub empty check in progress
- CdCool down, drying cycle finished
- CEMotor current error
- CLChild lock is on
- CLChild lock released and water drained
- dCDoor not detected as closed and locked
- dEDoor or lid not locked
- dEDoor not detected as closed and locked
- dLDoor lock fault during the cycle
- dnSoftware download in progress
- DrDrained after a long pause
- E2Control panel button stuck
- E6Clutch or agitation drive fault on a top loader
- FEOverfill, water above the level the cycle asked for
- FEFan motor fault
- FFFreeze failure
- HEWater heater not functioning
- IEInlet error, no water reaching the tub
- LEMotor locked, drum will not turn
- OCOverflow, too much water in the tub
- OEOutlet error, water not draining
- OEOverflow, too much water in the tub
- PEPressure sensor error
- PFPower failure recorded
- SUdExcess suds
- SUDExcess suds, too much foam
- tCLTub clean cycle is due
- tETemperature sensor error
- tETemperature sensor fault
- UCSupply voltage fluctuation
- UEUnbalanced load, spin will not start
- UEUnbalanced load, spin will not start
- vSVibration sensor fault
Water Heater47 codes
- 1 flash every 2 secondsStandby, waiting for a call for heat
- 2 flashesFlue damper test circuit not working, damper stuck open
- 03Dipswitch setting does not match the installation
- 3 flashesFlue damper test circuit not working, damper not fully open
- 4 flashesExcessive tank temperature
- 5 flashesUndesired false pilot flame present
- 7 flashesFlammable vapour sensor or resettable thermal switch fault
- 8EElectrical noise reported on the control board
- 10Warning for the combustion lockout
- 11Ignition failure, the burner never lit
- 12Loss of flame after ignition
- 32Temperature sensor open or shorted
- 39Air-fuel ratio rod fault
- 55Gas valve or valve circuit fault
- 61Induced draft fan fault
- 61 flashFailed to light the pilot, unit auto resets
- 62 flashesFlue damper moved off fully open during the run
- 63 flashesPilot flame extinguished, unit auto resets
- 64 flashesUndesired false pilot flame sensed, unit auto resets
- 70Control board fault
- 72False flame detected
- 74Remote controller communication fault
- 81 flashFlammable vapour sensor out of specification
- 82 flashesTemperature sensor fault
- 83 flashesGas control electronics fault
- 84 flashesGas valve fault detected
- 91 flashInsufficient combustion air detected
- 92 flashesCombustion chamber temperature sensor out of specification
- 99Incomplete combustion, unit locked out
- A2Overheat protection tripped, flue gas limiter or overheat fuse
- A7Hot water temperature sensor fault or out of range
- A9Outlet temperature sensor not seeing the set temperature
- C1Fan rotation too low at start-up
- C6Fan rotation too low during operation
- C7No fan speed signal from the fan
- CAWater flow above the specified maximum
- E0Control board software or hardware failure
- E1Over temperature at the hot water sensor
- E2Inlet temperature sensor fault
- E9Overheat sensor opened circuit
- EANo ionization during the safety time, failed to ignite
- ECLoss of burner flame while burning
- F7Flame sensed while the unit is in standby
- FAGas valve not closing the gas circuit
- HeartbeatThermostat calling for heat, normal operation
- No lightNo status light, unit is not powered
- Weak pilot signalWeak pilot signal on the last call for heat
Mini Split39 codes
- 1 blink, 2.5 s OFFRoom temperature thermistor, or indoor outdoor communication error
- 2 blinks, 2.5 s OFFIndoor coil thermistor, or outdoor power system
- 3 blinks, 2.5 s OFFSerial signal, or one of six outdoor thermistors
- 4 blinks, 2.5 s OFFOvercurrent, or compressor startup failure
- 5 blinks, 2.5 s OFFDischarge over-temperature, compressor stopped
- 6 blinks, 2.5 s OFFHigh pressure protection
- 7 blinks, 2.5 s OFFInverter or control board over-temperature
- 8 blinks, 2.5 s OFFOutdoor fan motor
- 9 blinks, 2.5 s OFFControl board memory, or a shorted power module
- 10 blinks, 2.5 s OFFDischarge temperature too low, starved compressor
- 11Serial communication error
- 11 blinks, 2.5 s OFFIndoor fan motor, or outdoor bus voltage and phase current
- 12Wired remote controller or server room control communication error
- 12 blinks, 2.5 s OFFIndoor control board memory
- 14 blinks, 2.5 s OFFClosed stop valve, or four way valve and pipe temperature
- 15Check run unfinished or automatic airflow adjustment error
- 16 blinks, 2.5 s OFFRefrigerant system abnormality, closed valve or air trapped
- 18External communication error
- 23Combination error
- 32Indoor unit PCB model information error
- 35Manual auto switch error
- 41Room temperature sensor error
- 42Indoor heat exchanger middle temperature sensor error
- 44Human sensor error
- 51Indoor unit fan motor error
- 62Outdoor unit main PCB model information or communication error
- 63Inverter error
- 64Active filter or power factor correction circuit error
- 65Trip terminal L error
- 71Discharge temperature sensor error
- 73Outdoor heat exchanger liquid temperature sensor error
- 74Outdoor temperature sensor error
- 84Current sensor error
- 94Trip detection
- 95Compressor rotor position detection error
- 97Outdoor unit fan motor 1 error
- 99Four way valve error
- A1Discharge temperature error, compressor over-temperature
- Lamp offNo blinking, normal operation
Fridge30 codes
- 5EDefrost sensor fault
- 8EIce maker sensor fault
- 21EFreezer fan motor fault
- 22EFresh food fan motor fault
- 23ECondenser fan fault
- 33EIce pipe heater fault
- 39EIce maker function error
- 40EIce room fan fault
- 41CSoftware update condition
- 76CWater in the autofill compartment
- 84CCompressor lock
- 85CLow supply voltage recorded
- 88 88Power interruption or communication reset
- APAccess point mode
- CFCondenser fan fault
- CLChild lock is on
- COCommunication error between the main board and the display
- dHDefrost did not complete in the time allowed
- dSDefrost sensor short or disconnected
- EIDFreezer ice maker sensor fault
- FFFreezer fan fault
- FSFreezer sensor short or disconnected
- HSHumidity sensor short or disconnected
- IFIce maker fan fault
- ItIce maker defect
- OF FDemo mode is on
- OF OFCooling off mode is on
- PC ERPanel communication error
- rFRefrigerator fan fault
- rSRefrigerator sensor short or disconnected
Dryer28 codes
- 3EInverter motor fault
- 5CDrain fault on a steam model
- 9C1Supply voltage irregularity
- ACCommunication error between boards
- bEPanel button stuck or continuously pressed
- C90Vent more than 90 percent blocked
- CLChild lock is on
- d80Exhaust duct about 80 percent blocked
- d90Exhaust duct 90 percent or more blocked
- dEDoor not completely closed
- dEDoor not detected as closed
- dnFirmware download in progress
- E13Drain hose kinked or frozen, heat pump model
- F0Filter needs attention
- FCInvalid power source frequency
- gASGas supply fault
- HCOverheat, cycle stopped for safety
- HC2Gas ignition failure
- HSHumidity sensor fault
- LE1Motor locked or blocked
- NCCheck the lint filter
- nPNo current detected at the heater
- oDDry time error, load not drying
- PFPower failure recorded
- PSSupply cord wired with reversed polarity
- tEAir temperature sensor fault
- tE1Drum outlet thermistor fault
- tE2Inlet or steam thermistor fault
AC9 codes
- 1 flashLong compressor run time
- 2 flashesHigh or low pressure switch trip
- 3 flashesCompressor short cycling
- 4 flashesCompressor locked rotor
- 5 flashesOpen compressor circuit or low incoming voltage
- 6 flashesOpen compressor start circuit
- 7 flashesOpen compressor run circuit
- 8 flashesWelded contactor
- 9 flashesLow pilot voltage
A code on its own is not enough
One flash on a Goodman GMV8 furnace is an ignition lockout. One flash on a Goodman AVPTC is an invalid heater kit. Four flashes on a GMV8 is an open high limit switch, while four flashes on a GMSS9 is a limit circuit open on a completely different control. Same number, different fault, different part.
That is why our URLs carry the model family, and why we would rather have you find your model number than read a confident wrong answer.
No code yet? Start from the symptom
Plenty of faults never display a code, or the control has been reset since it did. If you know what the machine is doing, open the section for that appliance and use the symptom list to work backwards to the likely component.
If you cannot find your model anywhere on the site, tell us the model number and we will verify it.
Request a model →