CABosch · Therm 250SX, GWH 635ES and 2400E gas tankless · Water Heater

Bosch Therm 250SX, GWH 635ES and 2400E gas tankless error code CA

Water flow above the specified maximum

Book a technician
Also written as flow rate, water pressure, gpm

Which models this applies to. This page covers the Bosch Therm 250SX, GWH 635ES and 2400E gas tankless codes.

What is specific to the Therm 250SX, GWH 635ES and 2400E gas tankless platform

Condensing gas tankless platform with a condensing heat exchanger, an induction fan and a flue gas limiter. Four of its codes, A2, A7, A9 and C1, mean something completely different on the Greentherm T9000 platform, and the gas pressure ranges published for it differ from the T9000 ranges, so the code has to be read against the model family rather than as a Bosch code.

Your control board prints the code as text, for example F01 or EE3, so you read it off the display rather than counting blinks. The printed number is the fault itself, not a position in a table.

Quick answer

On Bosch Therm 250SX, GWH 635ES and 2400E gas tankless, CA is a fault. It means water flow above the specified maximum. A first thing to check: Unusually high incoming water pressure.

Applies to
Bosch Therm 250SX, GWH 635ES and 2400E gas tankless
Bosch Therm 250SX, GWH 635ES and 2400E gas tankless codes · Water Heater
Type of code
Fault
Urgency: Book a technician
First safe check
Time the flow into a container of known volume to measure the actual rate. Over 10 GPM and the flow needs to be reduced.
Checked

What CA means on this model

The inlet flow sensor has measured more than about 10 gallons per minute through the unit. Bosch describes this as almost always a plumbing problem rather than a heater problem, usually unusually high incoming water pressure.

Symptoms you will notice

  • The unit shows CA
  • Hot water output is erratically cold when several fixtures run at once
  • The unit struggles to deliver hot water during heavy demand

Common causes

The code tells you what the control detected, not which part failed. These are the causes we see most often, roughly in order of likelihood:

  • Unusually high incoming water pressure
  • A pressure regulating or reducing valve that is failed or set too high
  • A plumbing change that increased available flow

What you can safely check

These are homeowner-level checks. None of them need you to open a live electrical compartment or work on gas.

  • Time the flow into a container of known volume to measure the actual rate. Over 10 GPM and the flow needs to be reduced.
  • Check the incoming water pressure and the setting on the pressure reducing valve if one is fitted.
  • Note whether the fault only appears when several fixtures are opened at the same time, which points at the incoming supply rather than the heater.

Do not do these

  • ×Do not attempt to override the flow limit in the control to run the unit at higher flow, since the rating exists for the combustion and heat transfer design.
  • ×Do not chase this fault inside the heater first. Bosch states explicitly that it is usually an external plumbing issue.

When to call a technician

Worth scheduling, and worth your own checks first

You can usually keep living with this for a short while, but it will not fix itself. Do the safe checks below first, because a tripped switch or a blocked airflow is a five-minute fix that would otherwise cost you a service call.

  • This is a fuel-burning appliance, so treat anything involving a burner, gas valve or flue as technician work. If you smell gas at any point, leave the property and call the gas utility from outside rather than continuing to diagnose.
  • If the appliance has stopped mid-cycle, is making a noise you have not heard before, or smells burnt, stop reading here and call. Those are symptoms of something the fault code does not describe well enough.

Measuring flow into a container is a homeowner task. Anything on the supply side beyond that is plumbing work.

What it costs to fix

Parts

Pressure reducing valve $30 to $120.

Labor

Fifteen minutes to measure flow, one to two hours to fit or reset a pressure reducing valve.

DIY or technician

Measuring flow into a container is a homeowner task. Anything on the supply side beyond that is plumbing work.

Typical US part and labor ranges, 2026. They vary by region, model and contractor, so treat them as a planning figure, not a quote.

Scope of this code

Code table
Bosch Therm 250SX, GWH 635ES and 2400E gas tankless codes
How this model reports the code
Printed on the control display
Models in scope
Bosch Therm 250SX, GWH 635ES and 2400E gas tankless
How this platform differs
Condensing gas tankless platform with a condensing heat exchanger, an induction fan and a flue gas limiter. Four of its codes, A2, A7, A9 and C1, mean something completely different on the Greentherm T9000 platform, and the gas pressure ranges published for it differ from the T9000 ranges, so the code has to be read against the model family rather than as a Bosch code.
Checked
Confirm on your own unit
Find the model number on the data plate, then check this code in the service manual for that model. Manufacturers revise code tables between model years, and a revised board can renumber a fault.

Related codes